Benchtop vs Fully Automatic SPI
Sampling beside the line or whole-board inspection under program control: coverage, labor and cost.
Both classes of system measure paste in 3D. A benchtop system measures selected locations on sampled boards. A fully automatic system measures every programmed pad without operator attention.
| Criterion | Benchtop (e.g. M500) | Fully automatic (e.g. A600) |
|---|---|---|
| Coverage | Selected locations on sampled boards | Every programmed pad on each inspected board |
| Operator involvement | Places and positions each board | Minimal once the program is running |
| Catches setup errors | Yes | Yes |
| Catches gradual drift | Yes, with regular sampling | Yes |
| Catches random single-board defects | Only if that board is sampled | Yes |
| Programming | Little or none | Per product, from Gerber data |
| Per-board traceability record | For sampled boards | For every inspected board |
| Best for | Process setup, sampling, stencil evaluation, high mix at lower volume | Higher volume, critical products, full coverage requirements |
| Footprint | Bench space | Machine footprint |
| Investment | Lower | Higher |
Many plants run both: a fully automatic system for production and a benchtop system for process development.
Which to Choose
Benchtop
Your print defects are mostly setup and drift problems, volumes allow meaningful sampling, or you want an engineering and stencil-qualification tool.
Fully automatic
You see isolated bad prints, your customer requires every board measured, or volume is too high for sampling to be representative.
Want a Recommendation for Your Line?
Tell us about your product and volumes and we will suggest the right class of system.